Tier II, Tier III
| Speed | 720rpm | 750rpm | ||
|---|---|---|---|---|
| Frequency | 60HZ | 50HZ | ||
| Eng.kW | Gen.kW | Eng.kW | Gen.kW | |
| 6H32DF-LM | 3,000 | 2,880 | 3,000 | 2,880 |
| 7H32DF-LM | 3,500 | 3,380 | 3,500 | 3,380 |
| 8H32DF-LM | 4,000 | 3,840 | 4,000 | 3,840 |
| 9H32DF-LM | 4,500 | 4,320 | 4,500 | 4,320 |
The alternator outputs are calculated for an efficiency of 96 % and a power factor of 0.8 lagging.
| Load | 720rpm | 750rpm |
|---|---|---|
| Heat Rate@Gas mode | 7,998 kJ/kWh | 8,197 kJ/kWh |
| SFOC@Diesel mode | 187 g/kWh | 189 g/kWh |
Methanol mode : 0.5 g / kWh + 1.1 liter / 24hrs per cylinder
Diesel mode : 0.5 g / kWh
| Speed | Cyl. | Dimension (mm) | Dry Mass (ton) | ||||
|---|---|---|---|---|---|---|---|
| A | B 1) | C 1) | H | Engine 2) | GenSet 1) 3) | ||
| 720 / 750rpm | 6 | 5,765 | 3,415 | 9,180 | 4,520 | 40.2 | 62.5 |
| 7 | 6,255 | 3,669 | 9,924 | 4,684 | 43.5 | 70.2 | |
| 8 | 6,881 | 3,923 | 10,804 | 4,684 | 46.7 | 77.8 | |
| 9 | 7,008 | 4,063 | 11,071 | 4,684 | 51.4 | 85.0 | |
| Fuel | Pros | Cons |
CO2 (Tank to propeller, Oil is 1.0) |
TRL1) (Technology Readiness Level) |
Fuel Cost (ton) |
Eng. Cost (Main Engine, oil is 1.0) |
|---|---|---|---|---|---|---|
| LNG |
|
|
0.8 | 9 | $310 | 1.4 |
| LPG |
|
|
0.9 | 9 | $340 | 1.5 |
| Methanol |
|
|
0.9 | 6 | $410 | 1.5 |
| Ammonia |
|
|
0.1 | 2 | $500 | 1.7 |
| Hydrogen |
|
|
0.0 | - | Over $10,000 | N/A |
| Fuel | Pros | Cons |
CO2 (Tank to propeller, Oil is 1.0) |
TRL1) (Technology Readiness Level) |
Fuel Cost (ton) |
Eng. Cost (Main Engine, oil is 1.0) |
|---|---|---|---|---|---|---|
| LNG |
|
|
0.8 | 9 | $310 | 1.4 |
| LPG |
|
|
0.9 | 9 | $340 | 1.5 |
| Methanol |
|
|
0.9 | 6 | $410 | 1.5 |
| Ammonia |
|
|
0.1 | 2 | $500 | 1.7 |
| Hydrogen |
|
|
0.0 | - | Over $10,000 | N/A |
| Property | MGO | LNG | LPG | Methanol | L_NH3 | L_H2 |
|---|---|---|---|---|---|---|
| Flash point [℃] | 52 | -188 | -105 | 11 | 132 | -150 |
| Auto ignition temperature [℃] | 250 | 595 | 459 | 464 | 651 | 535 |
| Boiling point at 1 bar [℃] | 20 | -162 | -42 | 20 | -34 | -253 |
| Low Heating Value [MJ/kg] | 42.7 | 50.0 | 46.0 | 19.9 | 18.6 | 120 |
| Density at 1 bar [kg/m3] | 870 | 470 | 580 | 792 | 682 | 71 |
| Energy density [MJ/L] | 36.6 | 21.2 | 26.7 | 14.9 | 12.7 | 8.5 |
| Fuel tank size | 1.0 | 1.7 | 1.4 | 2.5 | 2.9 | 4.3 |
| Ignition energy [MJ] | 0.23 | 0.28 | 0.25 | 0.14 | 8 | 0.011 |
| Flammable concentration range in the air [%] | 0.6 - 7.5 | 5 - 15 | 2.2 - 9.5 | 5.5 - 44 | 15 - 28 | 4 -75 |
| Property | MGO | LNG | LPG | Methanol | L_NH3 | L_H2 |
|---|---|---|---|---|---|---|
| Flash point [℃] | 52 | -188 | -105 | 11 | 132 | -150 |
| Auto ignition temperature [℃] | 250 | 595 | 459 | 464 | 651 | 535 |
| Boiling point at 1 bar [℃] | 20 | -162 | -42 | 20 | -34 | -253 |
| Low Heating Value [MJ/kg] | 42.7 | 50.0 | 46.0 | 19.9 | 18.6 | 120 |
| Density at 1 bar [kg/m3] | 870 | 470 | 580 | 792 | 682 | 71 |
| Energy density [MJ/L] | 36.6 | 21.2 | 26.7 | 14.9 | 12.7 | 8.5 |
| Fuel tank size | 1.0 | 1.7 | 1.4 | 2.5 | 2.9 | 4.3 |
| Ignition energy [MJ] | 0.23 | 0.28 | 0.25 | 0.14 | 8 | 0.011 |
| Flammable concentration range in the air [%] | 0.6 - 7.5 | 5 - 15 | 2.2 - 9.5 | 5.5 - 44 | 15 - 28 | 4 -75 |